Blanking Plate
Clamping Plate
with fold horizontal
Back of the Stove
Seal Blanking Plate
with fire cement
Fig. 12. Flue Blanking Plate.
Horizontal lengths of flue must be kept to a minimum and should not
be more than 150mm. The sealing face of the flue collar should be
coated with fire cement before fixing to the body of the stove using
the two screws provided. The blanking plate must be removed, sealed
with fire cement and refitted, care being taken to ensure that the fold
on the clamping plate is in line with the lugs on the firebox as shown
on the label on the clamping plate (see Fig. 12). Ensure that the
clamping plate does not prevent the throat plate from seating
correctly. All flue connections must be well sealed.
S O O T D O O R S
It is possible to pass a 16 inch diameter sweeps brush through the
appliance but in most back outlet installations it will be necessary to
have a soot door to enable the chimney to be swept. This may either
be in the actual brickwork of the chimney or in the register plate.
Various types and positions of soot doors are shown in figures 8-11.
T H E R M O S T A T
Before lighting the fire check the cold setting distance of the
thermostat. This is fitted under the firebox.
With the control knob at the minimum setting the flap should be just
closed as shown in Fig. 13. To adjust the distance slacken the locking
nut and adjust as necessary. When set correctly re-tighten the locking
nut. Ensure that the flap opens and closes freely as the knob is
turned, and that the opening is completely covered when the flap is
closed.
P R E L I G H T I N G C H E C K
Before initial lighting the following points should be checked :-
1. The bottom grate bars must all be fitted and should move freely and
easily when the riddling mechanism is operated.
2. The plates round the sides and back of the grate must be in position
and sitting correctly
3 The throat plate must be fitted in the roof of the appliance and should
be checked to ensure that it has not become dislodged in transit. The
method of location and positioning of the throat plate is shown in Fig. 4.
4. The central heating and hot water system must be correctly
connected and filled.
C O M M I S S I O N I N G
On completion of the installation and after allowing a suitable period
of time for the fire cement and mortar to dry out, the stove should
be lit and checked to ensure that smoke and fumes are taken from
the appliance up the chimney and emitted safely. Also check all joints
and seals. If the rear flue outlet is used, ensure that the front
throatplate (Item 16 on the Parts List) has been removed. On
completion of the installation and commissioning please leave the
operating instructions with the customer and advise them on the use
of the appliance.
Fig. 13. Thermostat Setting
Thermostat Flap
Locking Nut
Flap just closed with
knob at minimum
Thermostat
Arm