Charnwood C4 Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Herde Charnwood C4 herunter. Charnwood C4 Operating instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - C-SERIES

Operating & Installation Instructions charnwood®C-SERIES

Seite 2

either square or round and MUST NOT BE LESS THAN 125 mm (5") for C-Four and C-Five or 150mm (6") for C-Six, C-Seven and C-Eight.If an existi

Seite 3 - C O N T E N T S

sought either from the supplier or the local building inspector. The fireplace must allow good circulation of air around the appliance to ensure that

Seite 4 - OPERATING INSTRUCTIONS

SOOT DOORSPRE LIGHTING CHECKCOMMISSIONINGIt is possible to pass a 16 inch diameter sweeps brush through the appliance but in most back outlet installa

Seite 5

13EN13240:2001ROOMHEATERS FIRED BY SOLID FUELA Division of A.J.Wells & Sons Limited Registered in England No. 03809371 14Bishops Way, Newport, I

Seite 6 - Push up, twist one side down

®C-FOUR DIMENSIONS (mm)14 262 613 560 416 386 84 144 267 373 82 405 114 154 131 45 458 61 ID 64 OD

Seite 7

®C-FIVE DIMENSIONS (mm)Store Stand Standard ModelFront

Seite 8

®C-SIX DIMENSIONS (mm)16 505 63 79To suit 80mm ducting 161 292 441 615 411 670 119 398 169 131 88 441 146

Seite 9

®C-SEVEN DIMENSIONS (mm)17 800 855 529 185 564 292 690 244 292 160 615 534 564 670 398 169 130 146 440 85 505 59 79 OD 76 Store S

Seite 10 - INSTALLATION INSTRUCTIONS

®C-EIGHT DIMENSIONS (mm)Optional Vertical Rear Flue Adapter 500 710 764 465 292 163.0 76 79 61 605 185 470 895 949 500 292 246 790 1

Seite 11

Issue N 19®charnwoodT: +4 4 (0) 1983 537 79 9 • F:+ 44 (0 )198 3 537788 • SPAR ES @C HA RN WO OD .C OM • WW W.CHAR NWOOD. CO M BISHOPS W

Seite 13 - C SERIES

20®C-FIVE PARTS LISTIssue HItem Part No. Description Item Part No. Description1* 008/NR039 18mm Rope Door Seal (V2 Door) 32 004/CR041 Air Box Co

Seite 14 - C-FOUR DIMENSIONS (mm)

Issue K 21®charnwoodT: +4 4 (0) 1983 537 79 9 • F:+ 44 (0 )198 3 537788 • SPAR ES @C HA RN WO OD .C OM • WW W.CHAR NWOOD. CO M BISHOPS

Seite 15 - C-FIVE DIMENSIONS (mm)

Issue F 22®C-SEVEN PARTS LIST®charnwoodT: +4 4 (0) 1983 537 79 9 • F:+ 44 (0 )198 3 537788 • SPAR ES @C HA RN WO OD .C OM • WW W.CHAR NWO

Seite 16 - C-SIX DIMENSIONS (mm)

Issue F ®charnwoodT: +4 4 (0) 1983 537 79 9 • F:+ 44 (0 )198 3 537788 • SPAR ES @C HA RN WO OD .C OM • WW W.CHAR NWOOD. CO M BISHOPS W

Seite 17 - C-SEVEN DIMENSIONS (mm)

A D i v i s i o n o f A . J . W e l l s & S o n s L i m i t e d R e g i s t e r e d i n E n g l a n d N o . 0 3 8 0 9 3 7 1 charnwood

Seite 18 - C-EIGHT DIMENSIONS (mm)

C O N T E N T SO P E R AT I N G I N S T R U C T I O N SFuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Fitting The Riddling Grat

Seite 19 - C-FOUR PARTS LIST

These appliances have been approved by HETAS as intermittent operating appliances for burning dry seasoned wood logs only. HETAS approval does not cov

Seite 20 - C-FIVE PARTS LIST

LIGHTINGCONTROLLING THE FIREOn initial lighting, the stove may smoke and give off an odour as the silicon paint with which the firebox is painted reac

Seite 21 - C-SIX PARTS LIST

REDUCED BURNINGMAINTENANCEFor reduced burning the fire door must be closed.When burning wood in areas that are not smoke controlled, load some large

Seite 22 - C-SEVEN PARTS LIST

possible, do not try to fit too much fuel into the firebox.d) Do not completely close the air control.It is always more difficult to keep the glass cl

Seite 23 - C-EIGHT PARTS LIST

then be cleaned. If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately. After a chimne

Seite 24 - REV.C-Series v2 09.14

UNPACKING THE STOVEThe stove arrives bolted and shrink-wrapped to its pallet. There must be adequate facilities for unloading and manoeuvring into pos

Kommentare zu diesen Handbüchern

Keine Kommentare